Purpose: To evaluate the value of a fibrin-specific MR contrast agent (EP-2104R; EPIX Pharmaceuticals) for detection of deep vein thrombosis (DVT) and monitoring of percutaneous intervention for treatment.
Materials and methods: In 6 domestic swine, DVT was induced in an iliac/femoral vein using an occlusion-balloon catheter and subsequent injection of thrombin. The occluded vessels were recanalized by mechanical thrombectomy using a Fogarty catheter and an Arrow rotating thrombectomy device. Magnetic resonance imaging of the pelvis and lung was repeated 4 times (before and after DVT induction, after contrast agent administration, and after intervention) using a 1.5-T whole-body XMR system (ACS-NT, Philips Medical Systems, Best, NL). The visualization of the thrombi and contrast-to-noise ratio (CNR) was assessed.
Results: EP-2104R allowed selective visualization of thrombi with accurate determination of the extent of DVT with high contrast (CNR: 65.3 +/- 17.2). After intervention, dislodged thrombus fragments were selectively visualized in the lung (CNR: 27.9 +/- 9.3).
Conclusions: Molecular magnetic resonance imaging using fibrin-specific MR contrast agent EP-2104R allowed for selective visualization of DVT and monitoring of percutaneous intervention.