Contraction stress of low-shrinkage composite materials assessed with different testing systems

Dent Mater. 2010 Oct;26(10):947-53. doi: 10.1016/j.dental.2010.05.007. Epub 2010 Jun 20.

Abstract

Objectives: The contraction stress of a silorane-based material and a new low-shrinkage nanohybrid composite were compared to three conventional dimethacrylate-based resin composites using two different measuring systems. It was hypothesized that the silorane-based material and the low-shrinkage nanohybrid composite would exhibit lower contraction stress than dimethacrylate-based composites irrespective of measuring system.

Methods: The materials tested were Filtek Silorane LS (3M ESPE), Venus Diamond (Heraeus Kulzer), Tetric EvoCeram (Ivoclar Vivadent), Quixfil (Dentsply DeTrey), and Filtek Z250 (3M ESPE). Shrinkage stress was assessed using a stress-strain analyzer consisting of two opposing attachments, one connected to a load sensor and the other fixed to the device, or a system fixed to a universal testing machine with an extensometer as a feedback system. All specimens were light-cured with 20 J/cm(2); the contraction force (N) generated during polymerization was continuously recorded for 300 s. Contraction stress (MPa) was calculated at both 40 s and 300 s. Data were statistically analyzed by three-way ANOVA and Tukey's post hoc test (alpha=0.05).

Results: Venus Diamond exhibited the lowest stress under both experimental conditions. Stress values scored as follows: Venus Diamond<Tetric EvoCeram<Filtek Silorane LS<Quixfil<Filtek Z250 (p<0.05). Stress values measured with the stress-strain analyzer were significantly lower than those measured with the universal testing machine with feedback.

Significance: The hypothesis was partially rejected because only Venus Diamond exhibited the lowest stress values among the tested materials. Contraction stress was higher for all composites when measured in a test system with a feedback. This study confirms that simply reducing the shrinkage does not ensure reduced stress development in composites.

MeSH terms

  • Analysis of Variance
  • Composite Resins / chemistry*
  • Dental Marginal Adaptation
  • Dental Stress Analysis / methods*
  • Dentin-Bonding Agents
  • Light-Curing of Dental Adhesives*
  • Materials Testing / methods
  • Methacrylates
  • Nanocomposites
  • Silorane Resins
  • Siloxanes

Substances

  • Composite Resins
  • Dentin-Bonding Agents
  • Methacrylates
  • Silorane Resins
  • Siloxanes