Results from force fields implemented in HyperChem, a program frequently used in studies of bioactive compounds, have been compared using the example of the conformational analysis of a 1-carbonylthiosemicarbazide that exhibits strong antibacterial activity. By comparing these results with the original force fields and the experimental NMR ROESY spectrum, it was shown that these implementations can lead to erroneous results.