Transcatheter aortic valve implantation for patients with severe bicuspid aortic valve stenosis

Circ Cardiovasc Interv. 2013 Jun;6(3):284-91. doi: 10.1161/CIRCINTERVENTIONS.112.000084. Epub 2013 Jun 11.

Abstract

Background: Bicuspid aortic valve (BAV) is regarded as a relative contraindication to transcatheter aortic valve implantation attributable to the risk of uneven expansion of the bioprosthesis. The purpose of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation in patients with BAV.

Methods and results: Of 470 patients included in our prospective transcatheter aortic valve implantation database (October 2006-January 2012), 229 consecutive patients undergoing both echocardiography and multidetector computed tomography were analyzed. We compared clinical outcomes in patients with vs patients without BAV. In this series of 229 patients, BAV was detected by multidetector computed tomography in 21 patients (9.2%). BAV was identified by transthoracic and transoesophageal echocardiography in only 9 of these 21 patients. Patients were 83.1±6.6 years old, and European system for cardiac operative risk evaluation score was 20.0%±11.4%. The BAV group was similar to the non-BAV group except for diabetes mellitus (4.8% vs 24.0%; P=0.05). The aortic annulus diameter in BAV patients was not significantly larger by multidetector computed tomography (24.7±3.0 vs 23.7±1.9 mm; P=0.07). The CoreValve was used more frequently in the BAV group (47.6% vs 16.3%; P=0.002). There was no significant difference in device success (100% vs 92.8%; P=0.37), risk of annulus rupture (0% vs 1.4%; P=1.00), or valve migration (0% vs 1.4%; P=1.00) in BAV patients compared with non-BAV patients. Post-procedural mean gradient (10.0±3.4 vs 9.7±4.1 mm Hg; P=0.58), aortic regurgitation ≥2 of 4 (19.0% vs 14.9%; P=0.54), 30-day mortality (4.8% vs 8.2%; P=1.00), and 30-day combined safety end point (14.3% vs 13.5%; P=1.00) were also similar in both groups.

Conclusions: In selected BAV patients, transcatheter aortic valve implantation may be associated with low complication rate, efficacy, and acceptable outcomes similar to those in non-BAV patients.

Keywords: aortic stenosis; bicuspid aortic valve; computed tomography; echocardiography; transcatheter aortic valve implantation.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / abnormalities*
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Bicuspid Aortic Valve Disease
  • Cardiac Catheterization* / adverse effects
  • Cardiac Catheterization* / instrumentation
  • Cardiac Catheterization* / mortality
  • Echocardiography, Doppler, Color
  • Echocardiography, Transesophageal
  • Female
  • Heart Valve Diseases / diagnosis
  • Heart Valve Diseases / mortality
  • Heart Valve Diseases / therapy*
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Humans
  • Male
  • Multidetector Computed Tomography
  • Patient Selection
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Treatment Outcome