Long- and short-term indoor radon survey in the Ardea municipality, south Rome

Radiat Prot Dosimetry. 2014 Dec;162(4):625-9. doi: 10.1093/rpd/ncu025. Epub 2014 Feb 25.

Abstract

The indoor radon concentration was measured in 16 schools and 6 public departments in the Ardea municipality, using both active and passive detectors. The annual concentration of radon has been determined as the mean of two consecutive 6-month periods of sampling from January 2012 to January 2013. The indoor radon level measured in the monitored buildings ranged from 17 to 918 Bq·m(-3), with a mean value of 154 Bq·m(-3). In addition, the correlation between short-term and long-term measurements was studied. Experimental data demonstrate that the deviation of short-term measurements with respect to polyallyl diglycol carbonate data does not exceed ±40 % in a very extended range of radon concentrations.