A multiplexed three-dimensional paper-based electrochemical impedance device for simultaneous label-free affinity sensing of total and glycated haemoglobin: The potential of using a specific single-frequency value for analysis

Anal Chim Acta. 2016 Sep 14:936:1-11. doi: 10.1016/j.aca.2016.05.047. Epub 2016 Jun 3.

Abstract

A novel three-dimensional paper-based electrochemical impedance device (3D-PEID) is first introduced for measuring multiple diabetes markers. Herein, a simple 3D-PEID composed of a dual screen-printed electrode on wax-patterned paper coupled with a multilayer of magnetic paper was fabricated for label-free electrochemical detection. The results clearly demonstrated in a step-wise manner that the haptoglobin (Hp)-modified and 3-aminophenylboronic acid (APBA)-modified eggshell membranes (ESMs) were highly responsive to a clinically relevant range of total (0.5-20 g dL(-1); r(2) = 0.989) and glycated haemoglobin (HbA1c) (2.3%-14%; r(2) = 0.997) levels with detection limits (S/N = 3) of 0.08 g dL(-1) and 0.21%, respectively. The optimal binding frequencies of total haemoglobin and HbA1c to their specific recognition elements were 5.18 Hz and 9.99 Hz, respectively. The within-run coefficients of variation (CV) were 1.84%, 2.18%, 1.72%, and 2.01%, whereas the run-to-run CVs were 2.11%, 2.41%, 2.08%, and 2.21%, when assaying two levels of haemoglobin and HbA1c, respectively. The CVs for the haemoglobin and HbA1c levels measured on ten independently fabricated paper-based sheets were 1.96% and 2.10%, respectively. These results demonstrated that our proposed system achieved excellent precision for the simultaneous detection of total haemoglobin and HbA1c, with an acceptable reproducibility of fabrication. The long-term stability of the Hp-modified eggshell membrane (ESM) was 98.84% over a shelf-life of 4 weeks, enabling the possibility of storage or long-distance transport to remote regions, particularly in resource-limited settings; however, for the APBA-modified ESM, the stability was 92.35% over a one-week period. Compared with the commercial automated method, the results demonstrated excellent agreement between the techniques (p-value < 0.05), thus permitting the potential application of 3D-PEID for the monitoring of the glycaemic status in diabetic patients.

Keywords: 3-Aminophenylboronic acid; Eggshell membrane; Glycated haemoglobin; Haptoglobin; Label-free electrochemical detection; Three-dimensional paper-based electrochemical impedance device.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Biomarkers / blood
  • Biomarkers / chemistry
  • Blood Chemical Analysis / instrumentation*
  • Boronic Acids / chemistry
  • Diabetes Mellitus / blood
  • Electric Impedance*
  • Electrodes
  • Equipment Design
  • Glycated Hemoglobin / analysis*
  • Glycated Hemoglobin / chemistry
  • Humans
  • Limit of Detection*
  • Paper*
  • Time Factors

Substances

  • Biomarkers
  • Boronic Acids
  • Glycated Hemoglobin A
  • 3-aminobenzeneboronic acid