Reproducibility of Ablated Volume Measurement Is Higher with Contrast-Enhanced Ultrasound than with B-Mode Ultrasound after Benign Thyroid Nodule Radiofrequency Ablation-A Preliminary Study

J Clin Med. 2020 May 16;9(5):1504. doi: 10.3390/jcm9051504.

Abstract

The reproducibility of contrast-enhanced ultrasound (CEUS) and standard B-mode ultrasound in the assessment of radiofrequency-ablated volume of benign thyroid nodules was compared. A preliminary study was conducted on consecutive patients who underwent radiofrequency ablation (RFA) of benign thyroid nodules between 2014 and 2016, with available CEUS and B-mode post-ablation checks. CEUS and B-mode images were retrospectively evaluated by two radiologists to assess inter- and intra-observer agreement in the assessment of ablated volume (Bland-Altman test). For CEUS, the mean inter-observer difference (95% limits of agreement) was 0.219 mL (-0.372-0.809 mL); for B-mode, the mean difference was 0.880 mL (-1.655-3.414 mL). Reproducibility was significantly higher for CEUS (85%) than for B-mode (27%). Mean intra-observer differences (95% limits of agreement) were 0.013 mL (0.803-4.097 mL) for Reader 1 and 0.031 mL (0.763-3.931 mL) for Reader 2 using CEUS, while they were 0.567 mL (-2.180-4.317 mL, Reader 1) and 0.759 mL (-2.584-4.290 mL, Reader 2) for B-mode. Intra-observer reproducibility was significantly higher for CEUS (96% and 95%, for the two readers) than for B-mode (21% and 23%). In conclusion, CEUS had higher reproducibility and inter- and intra-observer agreement compared to conventional B-mode in the assessment of radiofrequency-ablated volume of benign thyroid nodules.

Keywords: contrast-enhanced ultrasound; observer variation; radiofrequency ablation; thyroid nodule; ultrasonography.