Can Circulating Tumor DNA Support a Successful Screening Test for Early Cancer Detection? The Grail Paradigm

Diagnostics (Basel). 2021 Nov 23;11(12):2171. doi: 10.3390/diagnostics11122171.

Abstract

Circulating tumor DNA (ctDNA) is a new pan-cancer tumor marker with important applications for patient prognosis, monitoring progression, and assessing the success of the therapeutic response. Another important goal is an early cancer diagnosis. There is currently a debate if ctDNA can be used for early cancer detection due to the small tumor burden and low mutant allele fraction (MAF). We compare our previous calculations on the size of detectable cancers by ctDNA analysis with the latest experimental data from Grail's clinical trial. Current ctDNA-based diagnostic methods could predictably detect tumors of sizes greater than 10-15 mm in diameter. When tumors are of this size or smaller, their MAF is about 0.01% (one tumor DNA molecule admixed with 10,000 normal DNA molecules). The use of 10 mL of blood (4 mL of plasma) will likely contain less than a complete cancer genome, thus rendering the diagnosis of cancer impossible. Grail's new data confirm the low sensitivity for early cancer detection (<30% for Stage I-II tumors, <20% for Stage I tumors), but specificity was high at 99.5%. According to these latest data, the sensitivity of the Grail test is less than 20% in Stage I disease, casting doubt if this test could become a viable pan-cancer clinical screening tool.

Keywords: cancer screening; circulating tumor DNA; clonal hematopoiesis; early cancer detection; liquid biopsy; molecular analysis; positive predictive value.