The sensitivity of Ho-phospholipid complexes to changes in the membrane viscosity of liposomes was checked. An increase in viscosity was observed for DPPC and DMPC near the phase-transition temperature. Ho-phospholipid complexes could be used as sensors of local membrane viscosity in NMR and MRI technologies.
Keywords: NMR; lanthanides; lipid membrane; membrane viscosity sensor; paramagnetic shift.