NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM123062 Query DataSets for GSM123062
Status Public on Sep 08, 2006
Title MAQC_ABI_3_D3
Sample type RNA
 
Source name MAQC sample D, i.e., MAQC samples A and B mixed at 25%:75% ratio (A:B).
Organism Homo sapiens
Characteristics NA

Extracted molecule total RNA
Label Chemiluminescence - Digoxigenin
Label protocol Digoxigenin-UTP labeled cRNA was generated from 1 µg of total RNA for each MAQC sample (A, B, C, D) using Applied Biosystems NanoAmp RT-IVT Labeling Kit (P/N 4365715) according to the manufacturer’s protocol.
 
Hybridization protocol Array hybridization, array processing, chemiluminescence detection, image acquisition, and analysis were performed using Applied Biosystems Chemiluminescence Detection Kit and Applied Biosystems 1700 Chemiluminescent Microarray Analyzer following manufacturer’s protocol.
Scan protocol Chemiluminescent Detection Kit (P/N 4339627, http://docs.appliedbiosystems.com/pebiodocs/04339627.pdf) and Chemiluminescent Microarray Analyzer User Guide (P/N 4338852B).
Description NA
Data processing The Expression Array System Software suite performs the auto-gridding, feature extraction, fluorescence normalization, and signal data generation. The quantification data contain many distinct measurements for each probe, including the three basic measurements: Signal, S/N, and Flag values. The Signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. The S/N value represents the ratio of signal above noise, or the measurement uncertainty of the probe signal, and can be used as a confidence level for the probe measurement. An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise. In situations where the probe showed S/N < 1, the signal measurement is replaced with a 1 SDEV upper limit based on its probe signal SDEV.
 
Submission date Jul 24, 2006
Last update date Aug 17, 2006
Contact name Leming Shi
E-mail(s) lemingshi@fudan.edu.cn
Phone +86-18616827008
Organization name Fudan University
Department School of Life Sciences
Lab Center for Pharmacogenomics
Street address 2005 Songhu Road
City Shanghai
ZIP/Postal code 200438
Country China
 
Platform ID GPL2986
Series (1)
GSE5350 MicroArray Quality Control (MAQC) Project

Data table header descriptions
ID_REF Manufacturer's probe ID
VALUE The signal value is the fully corrected, background subtracted measurement of chemiluminescent signal for gene expression values. Data were quantile-normalized per test site (20 arrays).
Flag_Detection An S/N of 3 represents approximately a 99.95% confidence that the probe is detected above the background noise.

Data table
ID_REF VALUE Flag_Detection
100002 93554.125 61.73
100003 125.279 -1.05
100027 156.376 1.29
100036 13946.298 21.32
100037 18801.602 49.92
100039 5347.063 20.26
100044 2796.951 33.48
100045 263.145 -2.14
100051 181.075 -1.02
100052 3529.871 13.45
100057 2480.062 7.26
100058 38999.543 52.33
100060 1109.78 7.03
100062 584.398 0.74
100064 1102.599 11.75
100079 101175.172 39.95
100089 12657.789 15.55
100093 4851.195 36.09
100095 464.85 1.78
100100 18236.189 42.35

Total number of rows: 32878

Table truncated, full table size 681 Kbytes.




Supplementary file Size Download File type/resource
GSM123062_ABI_3_D3.txt.gz 302.1 Kb (ftp)(http) TXT

| NLM | NIH | GEO Help | Disclaimer | Accessibility |