NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM205813 Query DataSets for GSM205813
Status Public on Sep 20, 2007
Title Gr1-_8h LM infected_3_peritoneal lavage
Sample type RNA
 
Source name infected peritoneal cells, timepoint 8h
Organism Mus musculus
Characteristics Six-weeks old (C57Bl6, Cx3cr1gfp/+) mice
infected with 1x104 of L. monocytogenes (EGDe strain) in exponential growth phase
timepoint:8h
Gr1- monocytes purified as NK1.1- CD3- B220- CD11b+ F4/80low Gr1-, gfphigh
Treatment protocol Cells were directly sorted in the SuperAmp Lysis Buffer (Miltenyi Biotec, Bergisch Gladbach, Germany) using a FACS Aria cell-sorter (BD biosciences). Cell samples (1.103 cells per experimental point) were lysed using SuperAmp Lysis Buffer following manufacturer’s instructions
Growth protocol Mice were intraperitonealy infected with 104 L. monocytogenes (EGDe strain) in exponential growth phase (bacteria were grown in BHI at 108/ml, and diluted 10.000x in PBS immediately before injection).
Extracted molecule polyA RNA
Extraction protocol SuperAmplification was performed according to Miltenyi Biotec’s undisclosed protocol. Briefly, the amplification is based on a global PCR protocol of mRNA-derived cDNA. mRNA was isolated via magnetic bead technology.
Label Cy3
Label protocol 250 ng of each of the cDNAs were used as template for Cy3 labeling which was performed according to Miltenyi Biotec’s undisclosed protocol.
 
Hybridization protocol Cy3 labeled cDNA in hybridization buffer was hybridized overnight (17 hours, 65°C) to an Agilent Whole Mouse Genome Oligo Microarrays (44K) using Agilent’s recommended hybridization chamber and oven.Finally, microarrays were washed once with 6x SSPE buffer containing 0.005% N-lauroylsarcosine for 1 min followed by a second wash with 0.06x SSPE containing 0.005% N-lauroylsarcosine for 1 min and a final wash step with acetonitrile for 30 sec. All washing steps were performed at room temperature.
Scan protocol Fluorescence signals of the hybridized Agilent Microarrays were detected using Agilent’s Microarray Scanner System (Agilent Technologies, Palo Alto, USA).
Description Cells were directly sorted in the SuperAmp Lysis Buffer (Miltenyi Biotec, Bergisch Gladbach, Germany) using a FACS Aria cell-sorter (BD biosciences).
Data processing The Agilent Feature Extraction Software (FES) was used to read out and process the microarray image files
 
Submission date Jun 26, 2007
Last update date Aug 14, 2011
Contact name Silvia Rueberg
E-mail(s) silvia@miltenyibiotec.de
Organization name Miltenyi Biotec GmbH
Department Genomic Services
Street address Friedrich-Ebert-Str. 68
City Bergisch Gladbach
ZIP/Postal code 51429
Country Germany
 
Platform ID GPL4134
Series (1)
GSE8294 Microarray analysis of monocytes recruited in the peritoneum during experimental infection with Listeria monocytogenes

Data table header descriptions
ID_REF
VALUE green_processed_Signal; the signal left after all the Feature extraction processing steps have been completed (e.g. background substraction)

Data table
ID_REF VALUE
12 0.17128
13 1.701067
14 0.223438
15 0.02948
16 0.646453
18 0.54273
19 0.014344
20 0.607065
21 0.295718
22 3.812966
23 0.12942
24 1.387405
25 3.357051
26 2.403266
27 1.293108
28 0.014733
29 0.106573
30 0.014866
31 0.01494
32 0.184339

Total number of rows: 43379

Table truncated, full table size 626 Kbytes.




Supplementary file Size Download File type/resource
GSM205813.txt.gz 6.8 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap