NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM290641 Query DataSets for GSM290641
Status Public on Oct 16, 2009
Title BH, biological rep3
Sample type RNA
 
Source name BH
Organism Mus musculus
Characteristics RAW 264.7 cell line
Biomaterial provider ATCC
Treatment protocol Samples were treated with 0.1 mg/mL Beta-Hematin. Immediately following treatment, lipopolysaccharide (LPS) was added at a final concentration of 1 μg/mL
Growth protocol Cells were cultured under standard incubation conditions (37 ºC, 5% CO2) and grown in RPMI supplemented with 5% FBS and 1μg/mL P/S
Extracted molecule total RNA
Extraction protocol Cells were harvested at 24 h using Versagene RNA purification and DNase treatment kits. Six wells of a 6-well plate were pooled for each biological replicate.
Label Digoxigenin
Label protocol All RNA Preps were run on an Agilent 2100 Bioanalyzer to assess RNA integrity. Those samples meeting minimum requirements of RIN value of 7.0 and greater were used to generate targets for hybridization to ABI arrays. One (1) ug of Total RNA (30ng mRNA) was used to generate First Strand cDNA using the NanoAmp RT-IVT labeling kit according to manufacturer’s protocol (ABI, Cat#4365715). Following first strand synthesis, second strand synthesis was completed. The resulting cDNA was then purified using an ABI kit provided column and the entire reaction was used in an IVT reaction to generate DIG labeled cRNA. The cRNA was then purified using a kit provided column and assessed for quality on an Agilent Bioanalyzer. All reactions meeting ABI criteria in terms of quantity and size of target produced were fragmented and then hybridized to the appropriate array for 16 hours with agitation at 55C.
 
Hybridization protocol All hybridization reagents, hybridization controls, wash reagents, and chemiluminescent reagents were provided in the ABI CL Detection Kit, part#4342142, and the manufacturer’s protocol was followed. Briefly, the arrays were equilibrated to room temperature and then pre-hybridized with a 1ml volume for 60’ with agitation (100RPM) at 55C per manufacturer’s protocol. During the pre-hybridization, the DIG-labelled targets were fragmented and then stored on ice until the pre-hyb was completed. Once pre-hyb was completed the targets were mixed with the appropriate reagents, including Hybridization controls, and the 0.5ml target was added to the pre-hybridization through the port on the array chamber. The arrays were immediately returned to the 55C Hybridization oven and agitated exactly 16 hours at 100RPM. The arrays were then washed and incubated with Anti-Dig-APAntibody for 20 minutes. Following antibody washes, the arrays were incubated with Chemiluminescence Enhancing Solution, washed a final time and then stored in the last wash buffer at room temperature. Substrate for the chemiluminescence reaction was added to each array individually and then the array was immediately imaged on the 1700 Chemiluminescent Analyzer.
Scan protocol Following addition of the chemiluminescence reaction substrate, each array was immediately imaged on the 1700 Chemiluminescent Analyzer. Each imaging was completed in approximately 15 minutes and the images were assessed for QC/QA and a primary analysis was completed by the AB1700 Expression Array System Software (v 1.1.1).
Description DWW21
Data processing Signal intensities across microarrays were quantile normalized
 
Submission date May 22, 2008
Last update date Oct 22, 2008
Contact name David W Wright
E-mail(s) David.Wright@vanderbilt.edu
Phone 615-322-2636
Fax 615-343-1234
Organization name Vanderbilt University
Department Chemistry
Street address SC Stevenson Center 7, Station B 351822
City Nashville
State/province TN
ZIP/Postal code 37235-1822
Country USA
 
Platform ID GPL2995
Series (1)
GSE13281 Expression profiles of beta-hematin (BH)- or 4-hydroxy-2-nonenal (HNE)-treated RAW 264.7 cells

Data table header descriptions
ID_REF
VALUE Quantile normalized signal intensity but with flagged values removed
SIGNAL_RAW Raw signal intensity
SDEV Noise/background signal intensity
CV Coefficient of variation of signal intensity based on the error model built into the Applied Biosystems image analysis software
S/N Signal-to-Noise ratio. Used for probe detectability (a probe with S/N >= 3 is considered detected)
FLAG Quality of each probe (FLAG > 5000 indicates quantification error)
UNF_VALUE Quantile normalized signal intensity

Data table
ID_REF VALUE SIGNAL_RAW SDEV CV S/N FLAG UNF_VALUE
297784 115470.254 88666.34 1143.42 0.08 77.55 0 115470.254
297907 1305.746 961.11 645.17 0.67 1.49 0 1305.746
297912 2011.848 1352.25 384.21 0.29 3.52 0 2011.848
297935 122.2986667 129.44 129.44 3.04 0.33 1 122.2986667
297990 2953.038667 1886.25 227.22 0.14 8.3 0 2953.038667
297993 314.3486667 336.08 111.73 0.34 3.01 0 314.3486667
298000 29762.57067 20784.46 451.34 0.06 46.05 0 29762.57067
298038 324.9873333 345.15 163.76 0.48 2.11 0 324.9873333
298121 153.5966667 167.21 167.21 12.53 -0.08 1 153.5966667
298130 7592.549333 4800.73 1674.52 0.35 2.87 0 7592.549333
298143 383.4506667 393.15 393.15 1.2 -0.84 1 383.4506667
298150 274.7146667 298.37 298.37 0.64 -1.58 1 274.7146667
298151 284.562 307.92 307.92 0.62 -1.62 1 284.562
298155 259.5946667 283.02 267.96 0.95 1.06 0 259.5946667
298165 378.7326667 389.58 389.58 28.54 -0.04 1 378.7326667
298174 4799.165333 2995.88 214.38 0.09 13.97 0 4799.165333
298188 634.5653333 564.04 564.04 0.69 -1.46 1 634.5653333
298200 772615.5713 682803.46 7783.78 0.07 87.72 0 772615.5713
298246 219.0833333 239.52 239.52 2.52 0.4 1 219.0833333
298248 185.0553333 203.47 203.47 1.37 -0.73 1 185.0553333

Total number of rows: 33012

Table truncated, full table size 1792 Kbytes.




Supplementary data files not provided
Processed data included within Sample table