Novel MRI contrast agent for molecular imaging of fibrin: implications for detecting vulnerable plaques

Circulation. 2001 Sep 11;104(11):1280-5. doi: 10.1161/hc3601.094303.

Abstract

Background: Molecular imaging of thrombus within fissures of vulnerable atherosclerotic plaques requires sensitive detection of a robust thrombus-specific contrast agent. In this study, we report the development and characterization of a novel ligand-targeted paramagnetic molecular imaging agent with high avidity for fibrin and the potential to sensitively detect active vulnerable plaques.

Methods and results: The nanoparticles were formulated with 2.5 to 50 mol% Gd-DTPA-BOA, which corresponds to >50 000 Gd(3+) atoms/particle. Paramagnetic nanoparticles were characterized in vitro and evaluated in vivo. In contradistinction to traditional blood-pool agents, T1 relaxation rate as a function of paramagnetic nanoparticle number was increased monotonically with Gd-DTPA concentration from 0.18 mL. s(-1). pmol(-1) (10% Gd-DTPA nanoparticles) to 0.54 mL. s(-1). pmol(-1) for the 40 mol% Gd-DTPA formulations. Fibrin clots targeted in vitro with paramagnetic nanoparticles presented a highly detectable, homogeneous T1-weighted contrast enhancement that improved with increasing gadolinium level (0, 2.5, and 20 mol% Gd). Higher-resolution scans and scanning electron microscopy revealed that the nanoparticles were present as a thin layer over the clot surface. In vivo contrast enhancement under open-circulation conditions was assessed in dogs. The contrast-to-noise ratio between the targeted clot (20 mol% Gd-DTPA nanoparticles) and blood was approximately 118+/-21, and that between the targeted clot and the control clot was 131+/-37.

Conclusions: These results suggest that molecular imaging of fibrin-targeted paramagnetic nanoparticles can provide sensitive detection and localization of fibrin and may allow early, direct identification of vulnerable plaques, leading to early therapeutic decisions.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Animals
  • Arteriosclerosis / diagnosis
  • Arteriosclerosis / metabolism
  • Biotinylation
  • Contrast Media
  • Dogs
  • Fibrin / metabolism*
  • Fibrin / ultrastructure
  • Fluorocarbons
  • Humans
  • Image Enhancement
  • Jugular Veins
  • Magnetic Resonance Imaging / instrumentation
  • Microscopy, Electron, Scanning
  • Particle Size
  • Thrombosis / diagnosis*
  • Thrombosis / metabolism
  • Venous Thrombosis / diagnosis

Substances

  • Contrast Media
  • Fluorocarbons
  • Fibrin