Detection of chromium in wastewater from refuse incineration power plant near Poyang Lake by laser induced breakdown spectroscopy

Appl Opt. 2012 Apr 1;51(10):1552-7. doi: 10.1364/AO.51.001552.

Abstract

A laser induced breakdown spectroscopy (LIBS) system was developed for determination of toxic metals Cr in wastewater collected from a refuse incineration power plant near Poyang Lake. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on the surface of liquid. Experimental conditions were optimized for improving the sensitivity and repeatability of the LIBS system through a parametric dependence study in potassium bichromate (K(2)Cr(2)O(7)) aqueous solutions. Calibration curves for Cr I 425.43 and 357.87 nm lines are compared and the limit of detection is found to be 39 and 86 ppm, respectively. This calibration curve of Cr I 425.43 nm has been used for quantification of Cr in wastewater collected from a refuse incineration power plant near Poyang Lake where the concentration of Cr is found to be 97 ppm. The results between LIBS and standard analytical technique such as atomic absorption spectroscopy were compared, and the relative standard deviation was 8.5%.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Calibration
  • China
  • Chromium / analysis*
  • Garbage
  • Incineration*
  • Industrial Waste / analysis*
  • Lasers*
  • Power Plants*
  • Spectrophotometry, Atomic / methods
  • Spectrum Analysis / instrumentation*
  • Spectrum Analysis / methods
  • Water / analysis*

Substances

  • Industrial Waste
  • Water
  • Chromium