Stroke Risk as a Function of Atrial Fibrillation Duration and CHA2DS2-VASc Score

Circulation. 2019 Nov 12;140(20):1639-1646. doi: 10.1161/CIRCULATIONAHA.119.041303. Epub 2019 Sep 30.

Abstract

Background: Studies of patients with cardiovascular implantable electronic devices show a relationship between atrial fibrillation (AF) duration and stroke risk, although the interaction with CHA2DS2-VASc score is poorly defined. The objective of this study is to evaluate rates of stroke and systemic embolism (SSE) in patients with cardiovascular implantable electronic devices as a function of both CHA2DS2-VASc score and AF duration.

Methods: Data from the Optum electronic health record deidentified database (2007-2017) were linked to the Medtronic CareLink database of cardiovascular implantable electronic devices capable of continuous AF monitoring. An index date was assigned as the later of either 6 months after device implantation or 1 year after electronic health record data availability. CHA2DS2-VASc score was assessed using electronic health record data before the index date. Maximum daily AF burden (no AF, 6 minutes-23.5 hours, and >23.5 hours) was assessed over the 6 months before the index date. SSE rates were computed after the index date.

Results: Among 21 768 nonanticoagulated patients with cardiovascular implantable electronic devices (age, 68.6±12.7 years; 63% male), both increasing AF duration (P<0.001) and increasing CHA2DS2-VASc score (P<0.001) were significantly associated with annualized risk of SSE. SSE rates were low in patients with a CHA2DS2-VASc score of 0 to 1 regardless of device-detected AF duration. However, stroke risk crossed an actionable threshold defined as >1%/y in patients with a CHA2DS2-VASc score of 2 with >23.5 hours of AF, those with a CHA2DS2-VASc score of 3 to 4 with >6 minutes of AF, and patients with a CHA2DS2-VASc score ≥5 even with no AF.

Conclusions: There is an interaction between AF duration and CHA2DS2-VASc score that can further risk-stratify patients with AF for SSE and may be useful in guiding anticoagulation therapy.

Keywords: atrial fibrillation; pacemaker, artificial; stroke.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Atrial Fibrillation / complications*
  • Atrial Fibrillation / diagnosis
  • Atrial Fibrillation / mortality
  • Databases, Factual
  • Decision Support Techniques*
  • Electronic Health Records
  • Female
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Prognosis
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stroke / diagnosis
  • Stroke / etiology*
  • Stroke / mortality
  • Time Factors