Objectives: We performed an environmental sampling study to investigate the environmental contamination of SARS-CoV-2 by COVID-19 patients with prolonged PCR positive status of clinical samples.
Methods: We sampled the air from rooms for nine COVID-19 patients with illness or positive PCR > 30 days, before and after nasopharyngeal/oropharyngeal swabbing and before and after nebulization treatment. We also sampled patients' surroundings and healthcare workers' personal protection equipment (PPE) in a non-ICU ward. SARS-CoV-2 was detected by PCR.
Results: Eighty-eight samples were collected from high-touch surfaces and floors in patient rooms and toilets, with only the bedsheets of two patients and one toilet positive for SARS-CoV-2. All air samples (n = 34) were negative for SARS-CoV-2. Fifty-five samples collected from PPE were all negative.
Conclusion: Contamination of near-patient surroundings was uncommon for COVID-19 patients with prolonged PCR positive status if environmental cleaning/disinfection were performed rigorously. Airborne transmission of SARS-CoV-2 was unlikely in these non-ICU settings.
Keywords: Air sampling; COVID-19; Corona virus disease 2019; Environment sampling; Healthcare workers; Personal protection equipment; SARS-CoV-2.