The diagnostic value of conventional radiography and musculoskeletal ultrasonography in calcium pyrophosphate deposition disease: a systematic literature review and meta-analysis

Osteoarthritis Cartilage. 2021 May;29(5):619-632. doi: 10.1016/j.joca.2021.01.007. Epub 2021 Feb 10.

Abstract

Objective: To examine and compare the accuracy of conventional radiography (CR) and musculoskeletal ultrasonography (US) in the diagnosis of calcium pyrophosphate (CPP) crystals deposition disease (CPPD).

Design: A systematic search of electronic databases (PubMed, Embase, and Cochrane), conference abstracts and reference lists was undertaken. Studies which evaluated the accuracy of CR and/or US in the diagnosis of CPPD, using synovial fluid analysis (SFA), histology or classification criteria as reference tests were included. Subgroup analyses by anatomic site and by reference test were performed.

Results: Twenty-six studies were included. Using SFA/histology as reference test, CR and US showed an excellent (CR AUC = 0.889, 95%CI = 0.811-0.967) and an outstanding (US AUC = 0.954, 95%CI = 0.907-1.0) diagnostic accuracy (p < 0.01), respectively. Furthermore, US showed a higher sensitivity (0.85, 95%CI = 0.79-0.90 vs 0.47, 95%CI = 0.40-0.55) and only a little lower specificity (0.87, 95%CI = 0.83-0.91 vs 0.95, 95%CI = 0.92-0.97) than CR. A considerable heterogeneity between the studies was found, with adopted reference test being the main source of heterogeneity. In fact, subgroup analysis showed a significant change in the diagnostic accuracy of CR, but not of US, using Ryan and McCarty criteria or SFA/histology as reference test (CR: AUC = 0.956, 95%CI = 0.925-1.0 vs AUC = 0.889, 95%CI = 0.828-0.950, respectively, p < 0.01) (US: AUC = 0.922, 95%CI = 0.842-1.0 vs AUC = 0.957, 95%CI = 0.865-1.0, respectively, p = 0.08) CONCLUSIONS: Although US is more sensitive and a little less specific than CR for identifying CPP crystals, both these two techniques showed a great diagnostic accuracy and should be regarded as complementary to each other in the diagnostic work-up of patients with CPPD.

Keywords: Calcium pyrophosphate deposition disease; Conventional radiography; Crystal arthropathy; Diagnostic accuracy; Ultrasonography.

Publication types

  • Comparative Study
  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Calcium Pyrophosphate / analysis
  • Chondrocalcinosis / diagnosis*
  • Fascia / diagnostic imaging
  • Humans
  • Joints / diagnostic imaging*
  • Ligaments, Articular / diagnostic imaging
  • Muscle, Skeletal / diagnostic imaging*
  • Radiography
  • Sensitivity and Specificity
  • Synovial Fluid / chemistry
  • Tendons / diagnostic imaging
  • Ultrasonography

Substances

  • Calcium Pyrophosphate